Cleaning the Streams Camera Window on the S3e™ Cell Sorter

In this video we show you how to clean the camera streams window as part of routine maintenance for your S3e Cell Sorter.
READ MORE →
Bench PartnersBench Partners Video SeriesChromatography VideoTips and Techniques VideoVideos

Attaching a Dynaloop to the NGC™ Chromatography System

This video describes the three main steps in attaching a DynaLoop Sample Loop to the NGC™ Chromatography System to enable the injection of larger sample volumes: connecting the DynaLoop Sample Loop to the NGC Chromatography System, priming the DynaLoop Sample Loop, and creating a method in ChromLab™ Software.
READ MORE →
Bench PartnersBench Partners Video SeriesChromatography VideoTips and Techniques VideoVideos

Calibrating the pH Valve on the NGC™ Chromatography System

The NGC pH valve provides real-time, in-line monitoring of buffer pH. In this video, you’ll learn how to connect the pH valve to the NGC System, add it to the flow path, and calibrate the valve using buffers at two different pH values. Features of the pH valve include accessible calibration ports and easy bypass of the probe when the NGC System is being cleaned.
READ MORE →
Bench PartnersBench Partners Video SeriesChromatography VideoTips and Techniques VideoVideos

Removing Air Bubbles from the NGC™ Chromatography System

This video explains how to remove bubbles and/or reduce bubble formation in your NGC System. Tips to reduce bubbles include warming up your multiwave detector for 30 to 60 min before use and flowing buffer at 0.1–0.2 ml/min in the manual mode until a stable/flat baseline is achieved before starting a method. The system may also be flushed with 100% methanol or ethanol at purge speed, with columns out of line, to remove bubbles.
READ MORE →
Bench PartnersBench Partners Video SeriesChromatography VideoTips and Techniques VideoVideos

Using the Air Sensor on the NGC™ Chromatography System

This video describes the functions of the Air Sensor Module and how to connect it to the NGC Chromatography System. The NGC Air Sensor senses the end of sample or buffer and prevents the introduction of air into the system, which can damage columns and/or incur the loss of precious samples. Both small and large air sensors are available to fit the tubing being used. Steps for connecting the Air Sensor Module and associated air sensors are described including how to add the air sensors into the system flow path using ChromLab™ Software and the differences in using the air sensors in manual vs. method modes.
READ MORE →
Droplet Digital PCR (ddPCR)Droplet Digital PCR (ddPCR) VideoVideos

Research Review: Phasing Genomes using
Droplet Digital™ PCR

Find out how a new Droplet Digital PCR-based technique called Drop Phase lets you quickly and easily phase genomes to better understand diseases like cystic fibrosis.
READ MORE →
Promos

Bioradiations May 2016 Edition

See what new articles and videos are in the May edition of Bioradiations.
READ MORE →
ArticlesChromatographyChromatography VideoProduct HighlightsVideos

How Do You Automate a Multicolumn Protein Purification?

Multicolumn purifications are tedious and the manual operations during this process introduce variabilities, affecting the success of purification and reproducibility of results. This whiteboard animation explains how an automated multi-dimensional chromatography method can make this an easier process with very high success rates.
READ MORE →